Thermocouple Issues
If it senses that your water heater pilot light keeps going out, the thermocouple will shift off the gas supply to the heater. Over time, thermocouples can malfunction, accumulate dust buildup, or the device can get bent away from the pilot light’s flame.
People also ask, can you clean a thermocouple?
Yes, you can clean a thermocouple, but the task must be done with a light touch. Remove the thermocouple from the process assembly, using a steel wool or emery cloth, lightly clean the tip removing any build up.
Also know, how do you fix a hot water heater that won’t stay lit?
How do you know if your water heater thermocouple is bad?
A worn out thermocouple is one of the most common gas water heater problems. When thermocouples wear out, the pilot light goes out, the burner won’t light, and you will have no hot water.
How long should a water heater thermocouple last?
In effect, new thermocouples were installed into contaminated tubes, causing the degradation of the sensors and generating greater than a 100°F shift in accuracy. In this scenario, thermocouple life, which should have been close to one year, was shortened to within a week.
How much does it cost to replace a thermocouple?
It costs $150 to $250 to replace a thermocouple. It checks to make sure the pilot light is on. It will shut the gas off if it’s not.
How much is a thermocouple?
1 cause of pilot lights that won’t stay lit is a worn-out thermocouple. It’s easy to replace and a new one costs $5 to $10. Rather than trying to unfasten the thermocouple inside the water heater’s burning chamber, it’s easier to remove the whole burner and thermocouple assembly.
Why does my gas water heater keep turning off?
If your gas water heater keeps turning off, the problem most likely lies with the thermocouple. This vital component detects when the pilot light is lit and then allows gas to flow to the burner. A faulty thermocouple will shut off gas to the burner as well as the pilot.
Why does my water heater burner won’t stay lit?
Thermocouple. If your gas water heater doesn’t stay lit, you may have a defective thermocouple. Most gas fired water heaters use a standing pilot to ignite the main burner. … Changing the thermocouple does not involve any gas fittings but local regulations may require that a qualified gas technician perform the repair.
Why does the pilot light go out?
Some of the possible serious reasons for pilot lights to go out include loose or broken gas valves, thermocouples or heat exchangers, faulty venting, low gas pressure, or high winds. If you believe there is a serious problem, don’t hesitate to contact a professional.