If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is a bad thermocouple. The good news: You can usually replace a thermocouple for minimal cost and in less than an hour.
Likewise, people ask, can I manually light my gas water heater?
Lighting a water heater is simple, no matter what type you have. Most newer models of gas water heaters have a simple ignition switch. In just a few steps the water heater is lit, no problem. If you’ve moved into an older house, though, you many have the kind of water heater that needs to be lit manually.
Also, can you clean a thermocouple?
Yes, you can clean a thermocouple, but the task must be done with a light touch. Remove the thermocouple from the process assembly, using a steel wool or emery cloth, lightly clean the tip removing any build up.
Does the pilot light stay on in a water heater?
Gas and propane fueled water heaters use a small flame to ignite the burner. This small flame is called a pilot light and it stays lit at all times. … But once the pilot light is relit, the water heater is able to ignite the gas burner and can begin to heat the water again.
How do I know if my thermocouple is bad?
If you can’t get the flame to light at all, and you’re sure the gas is on, there’s probably an obstruction in the pilot tube. If the flame lights and goes out when you release the gas control knob after holding it in for the recommended 20 to 30 seconds, that’s the sign of a thermocouple malfunction.
How do you clean a pilot tube?
How do you clean a thermocouple on a water heater?
Clean the thermocouple – using the emery cloth sandpaper, sand the ends of the thermocouple and then give it a finishing touch with the lint-free cloth. Hopefully, you can get to the ends of the thermocouple without having to detach it from the assembly, but you may have to do that.
How do you get a pilot light back on?
Turn the gas regulator valve to the “pilot” position. If the water heater has a manual “ignite” button, press that to light the pilot. If it doesn’t have the button, or the button fails, press the regulator valve and hold a grill lighter or long match to the pilot light valve until the pilot ignites.
How long does a water heater thermocouple last?
In effect, new thermocouples were installed into contaminated tubes, causing the degradation of the sensors and generating greater than a 100°F shift in accuracy. In this scenario, thermocouple life, which should have been close to one year, was shortened to within a week.
How much does a thermocouple cost?
It costs $150 to $250 to replace a thermocouple. It checks to make sure the pilot light is on. It will shut the gas off if it’s not.
How much does it cost to replace a water heater thermocouple?
Thermocouple – $20 to $150
The thermocouple is an apparatus that senses whether the pilot light is lit and triggers the gas control valve. Repairs typically cost about $150 to have it done professionally, though a new thermocouple itself only costs about $20 on average.
What causes a pilot light to not light?
Common Reasons Your Furnace Pilot Won’t Light
There are several possible reasons why your gas furnace pilot won’t light: an ongoing draft, a faulty thermocouple, an accumulation of dirt, or an inefficient supply.
Why is my gas heater not igniting?
The pilot light or ignition sensor is usually the most common issue when your furnace will not ignite. … Then, remove the front panel to find the ignitor or ignition sensor. This is typically located near the burners. If the sensor or ignitor is dirty, it will need to be cleaned.
Why would the pilot go out on water heater?
Some of the most common reasons that water heater pilot lights go out include: A faulty thermocouple. … Over time, thermocouples can begin to malfunction and shut off the gas supply to the pilot light even if it’s burning properly. A bent or dirty thermocouple.